Main Function:
- Used to measure the concentration of HC, CO, CO2, O2, NOx in the Automobile Exhaust Gas
- Used to measure opacity and light absorption coefficient, easy to operate
- Free acceleration experiments and adopts the transient measurement function, and automatic processing of test data and display measurements.
- Two kinds of Test Function for gasoline automotive: General and Two-speed idle
- Full English Menu Operation, LCD (Liquid crystal) screen display
- Automatic calculation and show the air-fuel ratio
- Equipped with RS232 digital serial communication interface to facilitate networking
- Equipped with functions of plate number and time display
- Can store and search 500 groups of data, built-in printer
- Measurable with Liquefied Petroleum Gas (LPG), Compressed Natural Gas(CNG),and gasoline and other alternative fuel vehicles
Main Technical Parameter
Measurement range:
CO: 0~ 10% CO2:0~20%
HC: 0~10000ppm O2: 0~25%
NOx: 0~5000ppm N: 0~99.9%
K:0~16.00m-1
Response Time:
CO, HC, CO2≤ 10S;
NOx, O2≤15S
Length of Optical channels: 215mm
Power: AC 220V; 50HZ
Preheating time:
Gas test: 10min; smoke test: 15min
Indication Error:
CO: ±5% CO2: ±5%
HC: ±5% O2: ±5%
NOx: ±5% Non-transparence
N:±2%
Gross weight:
Control unit: 6Kg, Test unit: 7.5Kg
Packing size:
Control unit: 620*495*325mm
Test unit:515*340*320mm